CORNING FAN-BT25-12 PDF

Discount Low Voltage only collects sales tax on orders shipped to California addresses. Tax will automatically be removed during checkout once a non-CA zip code is entered. For customers with a CA Resale Cert. Please check your local sales tax laws. All Rights Reserved. NetSuite Responsive Web Design.

Author:Tazahn Nikom
Country:Sweden
Language:English (Spanish)
Genre:Automotive
Published (Last):8 December 2005
Pages:287
PDF File Size:20.69 Mb
ePub File Size:16.4 Mb
ISBN:391-6-22540-626-7
Downloads:28732
Price:Free* [*Free Regsitration Required]
Uploader:JoJokree



Fan-Outs branch the fibers from a buffer tube into individual fibers protected by micron TFE protective tubing Figure 1. The fibers can then be connectorized according to hardware interface requirements. Outdoor application BTF kits resemble the indoor application kits. The BTF outdoor applications kit contains a two-part epoxy and a syringe which are used to fill the funnel section of the bottom part of a BTF assembly.

A BTF kit can be assembled any time after the cable sheath has been removed and the buffer tubes cleaned. Installation factors such as the length of cable slack available, the location of the terminating hardware, and the question of storing buffer tube slack as opposed to cable slack, can dictate when and where you choose to mount the cable end and assemble the BTF.

Determine the cable central member and strength member yarn lengths needed to secure the cable from the instructions provided with the hardware e. If you are working with a grease or gel-filled water-blocked cable, use a Fiber-Clean wipe to remove any flooding compound from the buffer tubes. Depending on the kit being used, measure 35, 46, or 57 inches of buffer tube from the end of the tubes.

Mark each tube with the permanent marker at this location. To minimize the chance of breaking a fiber, perform the remaining steps in this procedure one buffer tube at a time. Secure the cable end down to a work surface with tape so that the marks on the buffer tubes can reach the work surface edge see Figure 5. Select the first buffer tube. Remove the buffer tube back to the mark made in the previous section with a buffer stripping tool as described in SRP, Corning Cable Systems Stripping Tool for Buffers.

Tape down the buffer tube to receive the BTF so that 1 to 2 inches of tube overhang the work surface edge Figure 5. Carefully cut out any water block yarns with scissors Figure 6 and skip to Step 6. Use extreme care not to cut away any fibers. Use a clean lint-free tissue to thoroughly dry each fiber. Then run a dry finger along each fiber to check for any filing compound residue.

If residue is present on the fiber, repeat the cleaning process with a clean lint-free tissue until no residue remains. Make sure that the fibers are clean and dry. Any residue left on the fiber will obstruct threading operations into the micron assembly pieces. Do not deform or crush the buffer tube in the next step — doing so may cause bending in the fibers. Place the crimp tabs of the bottom piece of a BTF on the end of the buffer tube. Use pliers to gently bend the crimps tabs over the end of the buffer tube Figure 8.

Check the crimp for effectiveness by gently pulling on and twisting the tube — the tube should not move. The plastic section of the micron assembly has numbers on its plastic housing. The number 1, or blue tube, should be on the right front corner of the assembly see the inset of Figure 9. Carefully thread about three inches of the first fiber into the 1 blue micron tube Figure 9.

Repeat Steps 2 and 3 for the remaining fibers in sequential fiber order i. Work the threading process across the micron tube assembly in the proper order. Do not let any of the fibers cross each other during this threading operation. After all of the fibers have been inserted into the micron tubes, gently push the fibers into the tubes as a group until the fiber ends protrude from the ends of the tubes. Carefully pull the fibers out of the tube ends to take up most of the excess length between the BTF body and the micron assembly.

Leave a small fiber loop between the BTF body and the micron assembly to prevent fiber breakage during later steps in this procedure Figure Untape the micron assembly from the table edge. Carefully slide the assembly while gently pulling the bare fibers protruding from the micron tube ends until the assembly is above the fan-out body Figure At times the fibers will twist as a group when sliding the micron assembly towards the buffer tube.

Rotate the micron assembly opposite the direction of twist until the fibers straighten out. Severe twists left in the fibers could exhibit long term microbending effects on the fiber performance and add loss. Because buffer tubes are semi-rigid, they require careful handling to compensate for the tubes memory and springy nature.

Buffer tubes will tend to quickly return to their original position after handling. Whenever you use tape to anchor the tubes down, use care to control the tubes when removing the tape. Carefully remove the tape securing the buffer tube and reposition the BTF body on the work surface.

Retape the tube to hold the body in place. Remove the epoxy envelope from its foil packet. Fill the funnel section of the BTF bottom part with epoxy supplied in the outdoor applications kit as follows Figure 13 :. Align the top of the BTF body with the bottom and hand press them together until the top snaps into place Figure Separate another buffer tube and assemble the next BTF by repeating the steps in this section. Corning Cable Systems recommends working with the tubes in sequential order to maintain installation organization.

To aid in the identification and maintenance of the fan-out assemblies, use numbered wire markers to individually identify each BTF with respect to its buffer tube number if the tubes are not easily distinguished Figure Trim the excess fiber lengths to a length of 2 inches 5 cm from the end of the micron tubing. Terminate each fiber, working one BTF assembly at a time, following the instructions provided with the connectors.

Test the connectors in accordance with standard test procedures or any recommended test procedures supplied by the connector vendor. The BTF can be either bolted or taped into pieces of hardware. Refer to the instructions provided with the hardware being used to determine the best method. To route the BTF assembly into the hardware:. Carefully guide the BTF assembly into place, taking care to prevent the buffer tube from kinking at the entrance to the BTF body.

Cart 0. Cable Preparation A BTF kit can be assembled any time after the cable sheath has been removed and the buffer tubes cleaned. Step 1: Determine the total strip length requirement for your installation. Step 2: Mark this strip length from the end of the cable with a wrap of tape. Step 4: If you are working with a grease or gel-filled water-blocked cable, use a Fiber-Clean wipe to remove any flooding compound from the buffer tubes. Step 5: Depending on the kit being used, measure 35, 46, or 57 inches of buffer tube from the end of the tubes.

Buffer Tube Preparation Step 1: Secure the cable end down to a work surface with tape so that the marks on the buffer tubes can reach the work surface edge see Figure 5. Step 2: Select the first buffer tube. Step 3: Tape down the buffer tube to receive the BTF so that 1 to 2 inches of tube overhang the work surface edge Figure 5.

Step 4: If the buffer tube is Gel-free: Carefully cut out any water block yarns with scissors Figure 6 and skip to Step 6. Step 5: If the buffer tube is non-Gel-free: Use a clean lint-free tissue to thoroughly dry each fiber. Step 6: Place the crimp tabs of the bottom piece of a BTF on the end of the buffer tube.

Step 2: Separate and untangle the number 1 blue fiber back to the point it exits the buffer tube. Step 3: Carefully thread about three inches of the first fiber into the 1 blue micron tube Figure 9. Step 4: Repeat Steps 2 and 3 for the remaining fibers in sequential fiber order i. Step 5: After all of the fibers have been inserted into the micron tubes, gently push the fibers into the tubes as a group until the fiber ends protrude from the ends of the tubes.

Step 6: Carefully pull the fibers out of the tube ends to take up most of the excess length between the BTF body and the micron assembly. Step 7: Untape the micron assembly from the table edge. Step 8: Carefully remove the tape securing the buffer tube and reposition the BTF body on the work surface. Step Remove the epoxy envelope from its foil packet.

Fill the funnel section of the BTF bottom part with epoxy supplied in the outdoor applications kit as follows Figure 13 : Remove the divider between the two parts of the epoxy within the envelope. Thoroughly mix the epoxy by pulling the envelope repeatedly over the edge of the work surface or similar object.

Cut off one corner of the envelope. Pour at least 0. Fill the funnel section of the BTF bottom to overflowing. Do not leave any voids among the bifers in the funnel transition area Figure Properly dispose of the unused epoxy and syringe.

Step Align the top of the BTF body with the bottom and hand press them together until the top snaps into place Figure Step Remove the tape from the buffer tube. Step Separate another buffer tube and assemble the next BTF by repeating the steps in this section.

Marking the BTF To aid in the identification and maintenance of the fan-out assemblies, use numbered wire markers to individually identify each BTF with respect to its buffer tube number if the tubes are not easily distinguished Figure Fiber Termination Step 1: Trim the excess fiber lengths to a length of 2 inches 5 cm from the end of the micron tubing. Step 2: Terminate each fiber, working one BTF assembly at a time, following the instructions provided with the connectors.

Step 3: Test the connectors in accordance with standard test procedures or any recommended test procedures supplied by the connector vendor. Step 2: Carefully guide the BTF assembly into place, taking care to prevent the buffer tube from kinking at the entrance to the BTF body. Unavailable Sold Out.

MAGELLAN 5045-LM MANUAL PDF

How to Install Corning Outdoor Buffer Tube Fan Out Kit on Your Fiber Cable

The kits provide the most compact, easy-to-install fan-out solution requiring no additional hardware or space than that required for terminating tight-buffered cables. The Fan-Out Assembly is available with 6- or fiber units in lengths of 0. These different lengths provide the installer the fle. Write review.

VCO CHIP COOKBOOK PDF

CORNING FAN-BT25-12 FAN-OUT KIT

JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser. Click here to login or register your account. Business account customers will have access to account pricing and payment options.

CTSI PANCREATITIS PDF

FAN-BT25-12 - Corning Incorporated BUFFER TUBE FAN-OUT KIT, INDOOR, 12 F, 25-IN LEGS

.

CHS NC II REVIEWER PDF

Corning FAN-BT25-12 Indoor 12-Fiber Buffer Tube Fan-Out Kit

.

Related Articles