IMO MODU CODE 1989 PDF

Further amendments were adopted in May , to introduce the Harmonized System of Survey and Certification HSSC into the Code, provide guidelines for vessels with dynamic positioning systems and introduce provisions for helicopter facilities. This publication supersedes the edition and contains a consolidated text of the MODU Code and the and amendments. Unique international surveying qualification for offshore floating units — training course by tutored distance learning. The offshore industry differs from shipping in many ways and it is no longer enough to have just the core technical surveying skills. This professional development diploma has been designed to provide the necessary knowledge required for offshore surveyors to get and remain up to date and highly skilled. You can continue your studies by taking the MSc in Marine Surveying from Middlesex University which is available for graduates of the Diploma in Marine Surveying so you can enhance your Diploma qualification even further.

Author:Vushura Daikinos
Country:Sierra Leone
Language:English (Spanish)
Genre:Love
Published (Last):25 December 2018
Pages:419
PDF File Size:13.55 Mb
ePub File Size:1.78 Mb
ISBN:534-1-26155-447-4
Downloads:46277
Price:Free* [*Free Regsitration Required]
Uploader:Doutilar



Ga direct naar Inhoud of Menu. Bij klikken wordt een externe website met een relatieoverzicht geopend op overheid. Where 1. In all cases the intervals between any two such surveys should not exceed 36 months:. An administration may allow underwater inspections in lieu of a drydock survey provided that they are satisfied that such an inspection is equivalent to a drydock survey;.

They survey should be such as to ensure that the necessary repairs or renewals have been effectively made, that the material and workmanship of such repairs or renewals are in all respects satisfactory, and that the unit complies in all respects with the requirements of the Code. A copy of the continuous survey programme, together with the record of the surveys, should be kept on board the unit and the certificate annotated accordingly. The Administration may, however, entrust the inspections and surveys either to surveyors nominated for the purpose or the organizations recognized by it.

The Administration should notify the Organization of the specific responsibilities and conditions of the authority delegated to nominated surveyors or recognized organizations.

If such corrective action is not taken notified immediately: and, if the unit is in an area under the jurisdiction of another Government. When applicable, the Government of the port State concerned should ensure that the unit should not continue to operate until it can do so without danger to the unit or the persons on board.

If the unit is in an area under the jurisdiction of another Government, the Person in charge or the owner should also report immediately to the appropriate authorities of the port State and the nominate6 surveyor or recognized organization should ascertain that such a report has been made. The Certificate should be issued or endorsed either by the Administration or by any person or organization recognized by it.

In every case, that Administration assumes full responsibility for the certificate. Any certificate so issued should contain a statement to the effect that it has been issued at then request of the Government of the State the flag of which the unit is entitled to fly, and it should have the same force and receive the same recognition as a certificate issued under 1.

If the language used is neither English nor French, the tent should include a translation into one of these languages.

No certificate shall be extended for a period longer than three months, and a unit to which an extension is granted should not, on its arrival in the place in which it is to be surveyed, be entitled by virtue of such extension to leave that place without having a new certificate. When the renewal survey is completed, the new certificate shall be valid to a date not exceeding 5 years from the date of expiry of the existing certificate before the extension was granted.

In these circumstances, the new certificate shall be valid to a date not exceeding five years from the date of completion of the renewal survey. A new certificate should only be issued when the Government issuing the new certificate is fully satisfied th2;t the unit is in compliance with the requirements of 1. The Administration may allow a reduction in the total number of survival craft meeting this requirement when the unit is in the transit mode and the number of personnel on board has been reduced.

In such cases, sufficient survival craft to meet the requirements of this chapter, including Units on which night helicopter operations take place should have provisions to illuminate the wind direction indicator.

The width of the line should be 1 m;. The "H" should be 3 m high, 1. These lights should be uniformly positioned along the perimeter of the helideck and not more than 3 m apart.

The administration may allow the substitution of red lights for yellow lights to indicate the position of cranes, and in the case of self-elevating units, legs. The arrangements and aiming of floodlights should be such that helideck markings are illuminated and that shadows are kept to a minimum. Direct communications should be maintained with the crane operator throughout such operations.

The mooring positions should be such that sufficient crane capacity in terms of lift and outreach is available to handle loads in a safe manner. Details of future movements of units should also be passed to national hydrographic offices so that temporary notices may be promulgated before a unit gets under way. This person should be designated by title by the owner or operator of the unit or the agent of either of them. This person should be fully cognizant of his responsibilities for emergency organization and action, for conducting emergency drills and training, and for keeping records of such drills.

Manning of survival craft and supervision Muster list Drills should be so arranged that all personnel participate in a drill at least once a month. The Administration may accept other arrangements that are at least equivalent for those units for which this is impracticable. However, if the person is on a regularly scheduled rotating assignment to the unit, such training should be given not later than one week after the time of first joining the unit.

Individual instruction may cover different parts of the unit's life-saving system, but all the unit's life-saving equipment and appliances should be covered within any period of 2 months. Each regularly assigned person should be given instructions which should include but not necessarily be limited to:. Whenever practicable this should include the inflation and lowering of a liferaft. This liferaft may be a special liferaft intended for training purposes only, which is not part of the unit's life-saving equipment; such a special liferaft should be conspicuously marked.

The date when musters are held, details of abandonment drills, drills of other lifesaving appliances and on-board training should be recorded in such log-book as may be prescribed by the Administration. If a full muster, drill or training session is not held at the appointed time, an entry should be made in the log-book stating the circumstances and the extent of the muster, drill or training session held.

If questions are raised regarding the content, the original version of the regulatory framework as published through the official channels prevails. Zoeken op tekst Zoeken. Onderwerp: Home Zoekresultaten. Externe relaties. Maak een PDF. Permanente link. Ingangsdatum: Chapter 01 General Ingangsdatum: The modes of operation of a unit include the following:.

The unit may be either afloat or supported on the sea-bed, as applicable. In units designed with a rake of keel the waterline on which this length is measured should be parallel to the designed waterline.

In the case of column stabilized units a centralized ballast control station is a "control station". However, for purposes of the application of chapter 9, the space where the emergency source of power is located is not considered as being a control station.

They need meet neither requirements relative to the passage of smoke and flame nor limitations relative to the temperature rise. Where the words "steel or equivalent material" occur, "equivalent material" means any non-combustible material which, by itself or due to insulation provided, has structural and integrity properties equivalent to steel at the end of the applicable standard fire test e.

Public spaces are those portions of the accommodation which are used for halls, dining rooms, lounges and similar permanently enclosed spaces. This survey should be such as to ensure that the structure, equipment, fittings, arrangements and material fully comply with the applicable provisions of the Code. The periodical survey may be carried out while the unit is dry-docked or as otherwise indicated in 1. When the periodical survey is completed within 3 months before the expiration date of the existing Certificate, the new Certificate should be valid for a period of 5 years starting from the date of expiration of the existing Certificate.

The annual survey should be such as to ensure that the structure, fittings, arrangements, safety equipment and other equipment have been maintained in accordance with the applicable provisions of the Code and are in good working order. The annual surveys should be endorsed on the Certificate issued under the provisions of this section. The intermediate survey should be such as to ensure that the structure, fittings, arrangements, safety equipment and other equipment fully comply with the applicable provisions of the Code and are in good working order.

That portion, or portions, of the intermediate survey addressing structure may be carried out during the dry-dock survey. Such intermediate surveys should be endorsed on the Certificate Issued under the provisions of this section. However, the interval between any two dry-dock surveys should not exceed 36 months. An Administration may allow underwater inspections in lieu of dry-docking provided it is satisfied that such inspections are equivalent to a dry-dock survey.

Dry-dock surveys or equivalent underwater inspections should be endorsed on the Certificate issued under the provisions of this section. A copy of the approved continuous survey programme, together with the record of the surveys, should be retained on board the unit and the Certificate issued in accordance with 1.

The survey should be such as to ensure that the repairs or alterations have been effectively made, are in all respects satisfactory and fully comply with the applicable provisions of the Code. The Administration may, however, entrust the surveys either to surveyors nominated for the purpose or to organizations recognized by it.

In every case the Administration concerned should fully guarantee the completeness and efficiency of the surveys. In every case the Administration assumes full responsibility for the Certificate. If the language used is neither English nor French, the text should Include a translation into one of these languages. Such Certificate should he accepted unless there are clear grounds for believing that the condition of the unit or its equipment does not correspond substantially with the particulars of that Certificate and the operating manual.

In that case, the officer carrying out the control may take such steps as will allow the unit to operate on a temporary basis without undue risk to the unit and the personnel on board.

In the event of this control giving else to Intervention of any kind, the officer carrying out the control should inform the Administration or the Consul of the country in which the unit is registered in writing forth-with of all the circumstances in which intervention was deemed to be necessary, and the facts should be reported to the Organization. Chapter 02 Construction, strength and materials Ingangsdatum: Chapter 03 Subdivision, stability and freeboard Ingangsdatum: Chapter 04 Machinery installations for all types of units Ingangsdatum: Chapter 05 Electrical installations for all types of units Ingangsdatum: Chapter 06 Machinery and electrical installations in hazardous areas for all types of units Ingangsdatum: Chapter 07 Machinery and electrical installations for self-propelled units Ingangsdatum: Chapter 08 Periodically unattended machinery spaces for all types of units Ingangsdatum: Chapter 09 Fire safety Ingangsdatum: Chapter 10 Life-saving appliances Ingangsdatum: Radar transponder The radar transponders should either be stowed in locations from which they can be rapidly placed in any survival craft other than the liferaft or liferafts required by Chapter 11 Radiocommunication installations Ingangsdatum: Where there is common agreement, equipment type-approved by one Administration should be accepted by the other Administration.

Chapter 12 Lifting devices Ingangsdatum: The base of this sector should be tangent to the periphery of the circle described above, as shown in figure Administrations may specify different requirements if tandem rotor helicopters are to be utilized.

The overall length of a helicopter is the distance from the tip of the main rotor blade to the tip of the tail rotor when the rotor blades are aligned along the longitudinal axis of the helicopter. The outer edge should not rise more than 15 cm above the edge of the deck. These lights should be positioned around the perimeter of the deck not more than 3 m apart.

DURUSUL LUGHAH JILID 1 PDF

1989 MODU Code (2001 Edition)

Filter by Category. Filter by Region. Contact Us. Modu Code , Edition In stock.

IGRA STAKLENIH PERLI PDF

Modu Code 1989, 2001 Edition

.

GITTA MALLASZ PDF

.

Related Articles