It is able to offer cost-effective, state-of-the-art soil contaminant surveys with an unprecedented breadth of high precision data. These are the result of its unique combination of a PID analyser for measurement of total soil gas concentration and a selective IR analyser for the separate measurement of Methane, Petroleum Hydrocarbons and Carbon Dioxide. The resulting set of parameters is further complemented by temperature, pressure and Oxygen measurement. Data processing is managed using software compatible with Surfer and other mainstream graphic data processing systems. The most important subsurface factors that affect in-situ soil contamination measurements are:. Due to their inner structure, relatively impermeable soils such as clay produce soil vapors for much shorter periods of time compared to highly permeable soils such as sand.

Author:Kagashicage Akinoshakar
Country:Bahrain
Language:English (Spanish)
Genre:Health and Food
Published (Last):14 May 2015
Pages:136
PDF File Size:18.40 Mb
ePub File Size:1.32 Mb
ISBN:614-4-18714-155-3
Downloads:20790
Price:Free* [*Free Regsitration Required]
Uploader:Tojajin



It provides the user with the in-situ measurement of organic contaminants with selective analyses of methane, group of common petroleum hydrocarbons, CO 2 , O 2 , atmospheric pressure, sampling vacuum and soil temperature.

Visit the Technology Section on our website. It can make measurements repeatedly according to the pre-set measurement interval and automatically log the data to the internal disk. The setting of all the measurement parameters, as well as communication with the server can be set either individually at each station or remotely from the server.

The server can download the data from each station either automatically at pre-set intervals or data could be downloaded from any station at any time. All the stations could be connected via cellular network or via radio-modems. The server displays all the individual stations in the terrain map.

Clicking on the each station the server provides the history of measured data. The server can also announce the alarm if the measured value at any station exceed pre-set limit. All the remote control, as well as measured data download can be accessible via the Internet. Photo-ionization analyzer measures total level of volatile organic compounds VOCs and other toxic gases including chlorinated hydrocarbons to sub-ppb levels with the following characteristics:.

Infra-red analyzer comprises 4 independent channels for selective analyses of Methane, Petroleum Hydrocarbons and CO 2 with ppm resolution and the following characteristics:. Find out more or adjust your settings. This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings. If you disable this cookie, we will not be able to save your preferences. This means that every time you visit this website you will need to enable or disable cookies again.

Automatic re-zeroing before each measurement ensures perfect baseline stability and high accuracy of the resulting values. Ruggedized, light-weight and compact strong construction make it ideal for use in the field. Easy-to-read graphic display, user-friendly special operating system and data acquisition software. Automatic logging of all measured data. A powerful surface data-logging system for transparent, fast 3-D graphic visualization. Fully integrated automatic GPS position logger up to centimeter accuracy on request An integral user-calibration facility provides on-site fast calibration and advanced whole dynamic range calibration.

Reliable Oxygen reading. Possible integration to the monitoring stations network More detailed information can be found in our product brochures and in our technical factsheet. History of measurements at one station for all the selection of measurement channels. Table of one station measured value history.

Set-up of one monitoring station. Example of the map of the monitored area — 5 stations installed. Dimensions: x x mm including handle Weight: 3 kg Shipping Weight: 13 kg incl. Ruggedized, light-weight and compact of strong construction making it entirely suitable for the field environment.

A powerful surface data logging system for transparent and fast 3-D graphic visualization. An integral user calibration facility provides on-site fast calibration and advanced whole dynamic range calibration. PID Photo-ionization analyzer measures total level of volatile organic compounds VOCs and other toxic gases including chlorinated hydrocarbons to sub-ppb levels with the following characteristics: Detection limit: 2 ranges 0.

This website uses cookies to provide you with the best browsing experience. Privacy Overview This website uses cookies so that we can provide you with the best user experience possible. Strictly Necessary Cookies Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

Enable All Save Settings.

JEEP JK OWNERS MANUAL PDF

ECOPROBE 5 – Description

It provides the user with the in-situ measurement of organic contaminants with selective analyses of methane, group of common petroleum hydrocarbons, CO 2 , O 2 , atmospheric pressure, sampling vacuum and soil temperature. Visit the Technology Section on our website. It can make measurements repeatedly according to the pre-set measurement interval and automatically log the data to the internal disk. The setting of all the measurement parameters, as well as communication with the server can be set either individually at each station or remotely from the server.

BETTALE JAGATTU PDF

ECOPROBE 5 - rs dynamics

Diagrams and illustrations that are referenced in the text, are designated as Figures e. Once the impacted. In addition to the above paramete rs , temperature, pressure and oxygen are also measured. For more information kindly refer to the manual for communication and data acquisition software.

HJR 4102 PDF

.

KNUTH LITERATE PROGRAMMING PDF

.

Related Articles